Vector - Global Test Equipment https://4gte.com/product-category/signal-analyzers/vector-2/ Service, Solutions, Satisfaction Tue, 22 Jul 2025 18:48:23 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.2 https://4gte.com/wp-content/uploads/2025/05/logowithouttext-resized-250-x-250-100x100.gif Vector - Global Test Equipment https://4gte.com/product-category/signal-analyzers/vector-2/ 32 32 Keysight 89441A (89410A) VSA with W-CDMA Capability, DC to 2.65 GHz w/ Options 1C2/AY9/AYA/AYB/AYH/UFG https://4gte.com/products/hp-agilent-89441a-vsa-with-w-cdma-capability-dc-to-2-65-ghz-2/ Fri, 10 Aug 2018 11:43:22 +0000 http://globaltest.wpengine.com/?post_type=product&p=28319 The Agilent 89441A covers baseband through RF frequencies of DC to 2.65 GHz in scalar and vector analysis modes. The scalar RF instrument mode allows full-frequency coverage in spans to 2648 MHz.
Vector RF mode offers exceptional speed and additional signal processing for enhanced time-domain characterization and demodulation. Vector spans as wide as 7 MHz can be selected anywhere in the 2.65 GHz frequency range. A vector baseband mode is also available to provide all of the features and functionality of the Agilent 89410A. In vector RF mode, both phase and amplitude characteristics are captured in the time-series data. This information can be processed for narrow resolution spectrum analysis, AM/FM/PM demodulation, time selective analysis, vector modulation analysis (optional), and many other types of measurements.

The post Keysight 89441A (89410A) VSA with W-CDMA Capability, DC to 2.65 GHz w/ Options 1C2/AY9/AYA/AYB/AYH/UFG appeared first on Global Test Equipment.

]]>
DC to 2.65 GHz frequency range
Scalar and vector analysis modes
Full frequency coverage in spans to 2648 MHz
Exceptional speed and additional signal processing in RF mode for enhanced
time-domain characteristics and demodulation
Vector RF mode captures phase and amplitude characteristics in time-series
data
Optional digital radio and digital video demodulation

The post Keysight 89441A (89410A) VSA with W-CDMA Capability, DC to 2.65 GHz w/ Options 1C2/AY9/AYA/AYB/AYH/UFG appeared first on Global Test Equipment.

]]>
Keysight 89410A VSA with W-CDMA Capability, DC to 10 MHz https://4gte.com/products/hp-agilent-89410a-vsa-with-w-cdma-capability-dc-to-10-mhz/ Fri, 10 Aug 2018 11:40:40 +0000 http://globaltest.wpengine.com/?post_type=product&p=27109 The Agilent 89410A covers a frequency range of dc to 10 MHz and offers an optional second channel. The second channel makes it possible to measure frequency response or perform vector network analysis, and the built-in math functions facilitate measurement calibration and correction. Two-channel statistical measurements such as cross-correlation and coherence can also be made.
The 89410A provides a flexible source for circuit stimulation. Sinewaves, periodic chirps (sinewave sweeps), and pseudo-random noise are available, along with user-definable arbitrary waveforms. The arbitrary waveforms operate on a block of up to 4096 complex points. Any of these signals can be used as a stimulus while spectrum measurements are made elsewhere in the circuit. Source level and dc offset of the pattern are all controllable by the user.

The post Keysight 89410A VSA with W-CDMA Capability, DC to 10 MHz appeared first on Global Test Equipment.

]]>
DC to 10 MHz frequency range
Optional second channel
Accurate two channel statistical measurements such as cross-correlation
and coherence
Flexible source for circuit stimulation
Sine, periodic chirp, pseudo-random noise, and arbitrary source

The post Keysight 89410A VSA with W-CDMA Capability, DC to 10 MHz appeared first on Global Test Equipment.

]]>
Keysight 89431A 2.65 GHz RF Section https://4gte.com/products/hp-agilent-89431a-2-65-ghz-rf-section/ Fri, 10 Aug 2018 11:40:40 +0000 http://globaltest.wpengine.com/?post_type=product&p=27111 The 89431A RF Section has a frequency of 2.65GHz and converts an 89410A Vector Signal Analyzer to an 89441A VSB/QAM Signal Analyzer.

The post Keysight 89431A 2.65 GHz RF Section appeared first on Global Test Equipment.

]]>
The 89431A RF Section has a frequency of 2.65GHz and converts an 89410A Vector Signal Analyzer to an 89441A VSB/QAM Signal Analyzer.

The post Keysight 89431A 2.65 GHz RF Section appeared first on Global Test Equipment.

]]>
Keysight 89441A VSA with W-CDMA Capability, DC to 2.65 GHz https://4gte.com/products/hp-agilent-89441a-vsa-with-w-cdma-capability-dc-to-2-65-ghz/ Fri, 10 Aug 2018 11:40:40 +0000 http://globaltest.wpengine.com/?post_type=product&p=27113 The Agilent 89441A covers baseband through RF frequencies of DC to 2.65 GHz in scalar and vector analysis modes. The scalar RF instrument mode allows full-frequency coverage in spans to 2648 MHz.
Vector RF mode offers exceptional speed and additional signal processing for enhanced time-domain characterization and demodulation. Vector spans as wide as 7 MHz can be selected anywhere in the 2.65 GHz frequency range. A vector baseband mode is also available to provide all of the features and functionality of the Agilent 89410A. In vector RF mode, both phase and amplitude characteristics are captured in the time-series data. This information can be processed for narrow resolution spectrum analysis, AM/FM/PM demodulation, time selective analysis, vector modulation analysis (optional), and many other types of measurements.

The post Keysight 89441A VSA with W-CDMA Capability, DC to 2.65 GHz appeared first on Global Test Equipment.

]]>
DC to 2.65 GHz frequency range
Scalar and vector analysis modes
Full frequency coverage in spans to 2648 MHz
Exceptional speed and additional signal processing in RF mode for enhanced
time-domain characteristics and demodulation
Vector RF mode captures phase and amplitude characteristics in time-series
data
Optional digital radio and digital video demodulation

The post Keysight 89441A VSA with W-CDMA Capability, DC to 2.65 GHz appeared first on Global Test Equipment.

]]>
Keysight 89410-41903 Rubber Keypad for 89410A https://4gte.com/products/hp-agilent-89410-41903-rubber-keypad-for-89410a/ Fri, 10 Aug 2018 11:35:40 +0000 http://globaltest.wpengine.com/?post_type=product&p=24654 Agilent 89410-41903 Rubber Keypad for 89410A

The post Keysight 89410-41903 Rubber Keypad for 89410A appeared first on Global Test Equipment.

]]>
Agilent 89410-41903 Rubber Keypad for 89410A

The post Keysight 89410-41903 Rubber Keypad for 89410A appeared first on Global Test Equipment.

]]>
Keysight 89440A Vector Signal Analyzer, DC to 1.8 GHz https://4gte.com/products/hp-agilent-89440a-vector-signal-analyzer-dc-to-1-8-ghz/ Fri, 10 Aug 2018 11:33:12 +0000 http://globaltest.wpengine.com/?post_type=product&p=23377 Based on the 89410A baseband vector signal analyzer, the 89440A RF vector signal analyzer extends the frequency range of both receiver and source to 1.8 GHz with a 7-MHz information bandwidth. All of the vector capabilities of the 10-MHz baseband instrument {up to a 7-MHz information bandwidth) can be translated to any frequency from 0 to 1.8 GHz. The scalar RF instrument mode allows full-frequency coverage to 1798 MHz. Vector RF mode offers exceptional speed and additional signal processing for enhanced time-domain characterization and demodulation.

The post Keysight 89440A Vector Signal Analyzer, DC to 1.8 GHz appeared first on Global Test Equipment.

]]>
Based on the 89410A baseband vector signal analyzer, the 89440A RF vector signal analyzer extends the frequency range of both receiver and source to 1.8 GHz with a 7-MHz information bandwidth. All of the vector capabilities of the 10-MHz baseband instrument {up to a 7-MHz information bandwidth) can be translated to any frequency from 0 to 1.8 GHz. The scalar RF instrument mode allows full-frequency coverage to 1798 MHz. Vector RF mode offers exceptional speed and additional signal processing for enhanced time-domain characterization and demodulation.

The post Keysight 89440A Vector Signal Analyzer, DC to 1.8 GHz appeared first on Global Test Equipment.

]]>
Tektronix 1755A Waveform Vector Monitor https://4gte.com/products/tektronix-1755a-waveform-vector-monitor/ Tue, 10 Jul 2018 14:16:16 +0000 http://globaltest.wpengine.com/products/tektronix-1755a-waveform-vector-monitor/ Tektronix 1755A Waveform Vector Monitor

The 1755A features a common, straightforward operator interface, allowing the operator to take immediate advantage of the instrument's extensive feature set. Each operating mode provides a full set of operating controls, clearly labeled and within easy reach. Key controls are always available, with bezel buttons and knobs identified by intuitive on-screen labels.

The post Tektronix 1755A Waveform Vector Monitor appeared first on Global Test Equipment.

]]>
Tektronix 1755A Waveform Vector Monitor

The 1755A features a common, straightforward operator interface, allowing the operator to take immediate advantage of the instrument’s extensive feature set. Each operating mode provides a full set of operating controls, clearly labeled and within easy reach. Key controls are always available, with bezel buttons and knobs identified by intuitive on-screen labels.

 

The post Tektronix 1755A Waveform Vector Monitor appeared first on Global Test Equipment.

]]>
Keysight 89430A AY8, 2 MHz – 1.8GHz RF Section https://4gte.com/products/hp-agilent-89430a-ay8-2-mhz-1-8ghz-rf-section/ Mon, 10 Jun 2013 15:55:14 +0000 http://globaltest.wpengine.com/?post_type=product&p=33310 10 MHz to 1.8 GHz, Vector Signal Analyzer RF Section. Option AY8 convert HP 89410A to an HP 89440A. The Agilent 89430A increases the frequency range of the HP 89410A from dc - 10 MHz to 2 MHz - 1800 MHz. And increases the scalar frequency span on the top end from 10 MHz to 1798 MHz. Noise, amplitude and accuracy also improve.

The post Keysight 89430A AY8, 2 MHz – 1.8GHz RF Section appeared first on Global Test Equipment.

]]>
The option AY8 is an Internal RF Source- Retrofit at factory (HP 89440/430A)The 89440A vector signal analyzercover baseband through RF frequencies of dc to 1.8 GHz, in scalar and vectoranalysis modes. The scalar RF instrument mode allows full-frequency coverage inspans of 1798 MHz. Vector RF mode offers exceptional speed andadditional signal processing for enhanced time-domain characterization anddemodulation. Vector spans as wide as 7 MHz can be selected anywhere in the 1.8GHz frequency range. In vector RF mode, both phase and amplitudecharacteristics are captured in the time-series data. This information can beprocessed for narrow resolution spectrum anaysis, AM/FM/PM demodulation,time-selective analysis, and may other types of mesurements.

The post Keysight 89430A AY8, 2 MHz – 1.8GHz RF Section appeared first on Global Test Equipment.

]]>